The OPTIFLUX 2100 is an electromagnetic flowmeter (EMF) for standard water and wastewater applications. It is the ideal solution for all general flow applications where reliable flow measurement with sufficient yet not extremely high accuracy is required. Installation in measurement chambers subject to (constant) flooding is possible with the remote IP68 / NEMA 6P rated version.
Its wear resistant liner materials as well as its full bore design without moving parts make the OPTIFLUX 2100 an effective replacement of mechanical water meters in drinking water distribution networks. The meter features a wide range of approvals necessary for potable water measurement. A full on-site verification of the meter without process interruption can be carried out using the OPTICHECK service tool.
Bi-directional flow measurement over a wide dynamic range
Optional for subsoil installation and constant flooding
Proven and unsurpassed life time, huge installed base
Standard wet calibration
PP or hard rubber liner: suitable for low concentrated chemicals
Tamper proof
Standard measurement accuracy: ±0.3% or ±1mm/s of measured value (MV)
Diagnostics incl. conductivity, electrode error, ambient and process temperature etc.
Full bore design: No moving parts, no wear, no pressure loss
Meets potable water standards: ACS, DVGW, NSF, TZW, WRAS etc.
For hazardous areas: ATEX, IECEx, FM, CSA
On-site verification of flowmeter with OPTICHECK service tool
Field of use
Water and wastewater industry
Abstraction and irrigation
Monitoring of distribution networks
Water treatment plants (raw water, drinking water, treatment chemicals)
Wastewater networks
Combined and separate sewage systems
Storm water overflows (SWOs)
Municipal wastewater treatment plants
Desalination plants (sea water, permeate, brine)
Iron, metal and steel industry, chemical and other process industries
Industrial water (process or production water, cooling water, boiler feed water etc.)
Industrial wastewater collection, treatment and return flows
Ballast water, injection water etc.
Materials
Liner | Hard rubber, Polyolefin (PO), Polypropylene (PP) |
Process connections
Flange connections |
EN (1092-1): DN25…1200 |
Pressure rating (EN 1092-1) |
PN40 |
Pressure rating (JIS B 2220) |
20k |
Pressure rating (ASME B 16.5) |
Cl 300# |