Electromagnetic Flow meter OPTIFLUX 4400

The OPTIFLUX 4400 electromagnetic flowmeter (EMF) is developed in accordance with IEC 61508 for safety-related applications up to safety integrity level (SIL) 2/3. It features automated partial proof testing capabilities, which allows to extend the time interval between full proof tests and increase plant uptime in safety instrumented systems (SIS).

Next to safety applications, the OPTIFLUX 4400 is particularly suitable for process applications with high accuracy requirements and difficult flow conditions such as pulsating and turbulent flow. Due to its wide selection of lining and electrode materials it can well be used for flow measurement and dosing of chemicals and corrosive liquids such as acids. Utilising the EMF’s improved conductivity measurement, operators can also monitor a defined range of conductivity.

The OPTIFLUX 4400 comes with a wide range of flowmeter and process diagnostics for a high degree of reliability. Among others, it features a best-in class diagnostic test interval incl. fault response time of only 2 minutes. If running out of spec, the flowmeter is able to issue an alarm to the control room much faster than other EMFs available on the market. A full on-site verification of the OPTIFLUX 4400 without process interruption can be carried out using the OPTICHECK service tool.

Bi-directional flow measurement over a wide dynamic range (turn down ratio: 1000:1)

Available with patented virtual reference grounding method: no grounding rings needed

Extensive flowmeter and process diagnostics (incl. NE 107)

For hazardous areas: ATEX, IECEx, NEPSI, FM, CSA, EAC, INMETRO

Standard measurement accuracy: ±0.2% or ±1mm/s of measured value (MV)

For custody transfer: OIML R49, OIML R-117; MI-001, MI-004, MI-005

PTFE, PFA, ETFE, hard rubber, soft rubber or PU liner: excellent chemical and abrasion resistance

Wide range of electrode materials

Special designs, sizes, inner diameters and liner thicknesses on request

Optional external coatings for offshore or subsoil installation (also acc. to ISO 12944)

MATERIALS

 

Liner

Ethylene tetrafluoroethylene (ETFE),

Hard rubber,

Perfluoroalkoxy alkane (PFA),

Polytetrafluoroethylene (PTFE),

Polyuretane (PUR)

 

 

 

Process Connection

 

Flange Connecions

EN (1092-1): DN2.5…2000

(larger on request)

ASME (B 16.5): ⅒…80″

(larger on request)

JIS (B 2220): 2.5…1000A

 

 

Pressure rating (EN 1092-1)

PN40

 

 

Pressure rating (JIS B 2220)

20K

 

 

Pressure rating (ASME B 16.5)

CL300#