The TIDALFLUX 2300 is an electromagnetic flowmeter (EMF) with a patented, capacitive level measurement for use in partially filled pipes (up to DN1600 / 64”). The meter is the ideal solution for flow measurement of municipal or industrial wastewater in pressureless transport lines. However, the EMF is also suitable for measurement of effluent brine from dredging, mining or sea/well water injection applications. Unlike open channel systems (Venturi, V-notches etc.) the inline flowmeter is a closed measuring solution without obstructions and with a much better accuracy at lower total costs of ownership.
Bi-directional flow measurement over a wide dynamic range
Closed measurement solution with patented integrated non-contact level measurement
Designed for effluent and slurries in gravity pipelines / sewers
Chemically and abrasion resistant PUR liner
Accuracy: ±1% of measured value (MV)
Electrodes not in contact with floating deposits
Optional version for direct burial installation and flooded areas (IP68)
Standard factory calibration, no on-site calibration required
Extensive flowmeter and process diagnostics which exceed the NE 107 requirement also for use in
hazardous areas zone 1
On-site verification of flowmeter with OPTICHECK service tool
FIELD OF USE
Water and wastewater applications in partially filled and gravity feed pipes
Cost-effective replacement of expensive siphon tube constructions
Water and wastewater industry
Surface water
Biological and chemical wastewater
Combined and separate sewage systems
Combined sewer overflows (CSOs)
Storm water overflows (SWOs)
Rainwater retention basins
Influent/intake at wastewater treatment plants
Effluent of wastewater treatment plants
Discharge to surface water
Chemical and other process industries
Industrial wastewater collection and return flows
Control and monitoring of cooling water
Materials
Liner | Polyuretane (PUR) |
Process Connections
Flange connections | EN (1092-1): DN200…1600
ASME (B 16.5): 8…64″ |